LED_PHY4_OFF

CCU_SR PHY4 Fault

KUKA KRC4 · Sunrise Cabinet Med Controller

What does LED_PHY4_OFF mean?

The PHY4 LED on the CCU_SR module of the KUKA KRC4 Sunrise Cabinet Med Controller is OFF, indicating a fault condition. This typically relates to the physical layer transceiver for network communication, suggesting a problem with a network connection or the transceiver itself.

Common Causes

  • Internal malfunction of the PHY4 transceiver.
  • Network cable not properly connected or damaged.
  • Faulty CCU_SR module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check all network cables connected to the CCU_SR module for proper seating and physical damage.

  2. 2

    Power cycle the KUKA KRC4 Sunrise Cabinet Med Controller to reset the network transceivers.

  3. 3

    Observe other network-related LEDs (e.g., L/A KSB) for additional diagnostic information.

  4. 4

    If the fault persists after these checks, prepare to exchange the CCU_SR module.