EL
ErrorLib
Brands
||
  1. Home
  2. Kuka
  3. KK53Y Servo Motor
  4. MR9
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

MR9

Alarm Space 9 Violation

Kuka · KK53Y Servo Motor

What does MR9 mean?

The MR9 signal indicates a violation of monitoring space 9. A '0' state on this signal means that monitoring space 9 is currently being infringed upon. If monitoring space 9 is intentionally inactive, the system considers it violated by default, and the associated safe output MR9 will be in the '0' state.

Common Causes

  • Alarm condition triggered in Space 9 of the monitoring system.
  • Parameter P9 has exceeded its defined alarm threshold.
  • Sensor associated with Space 9 reporting an out-of-bounds value.
  • Configuration error in Space 9 alarm limits.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify the configured boundaries for monitoring space 9 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 9.

  3. 3

    If monitoring space 9 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR9 signal will default to a '0' (violated) state.

Browse all codes in this manual (17)
Verified technical data. Last updated: April 2026

Related Faults

JFMastering ErrorMR1Alarm Space 1 ViolationMR10Alarm Space 10 Violation
Source: Kuka KK53Y Servo Motor
Open Manual (Page 107)Search more codes in this manual