EL
ErrorLib
Brands
||
  1. Home
  2. Kuka
  3. KR C4 extended
  4. 26048
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

26048

Overvoltage during charging, KPP/KSP (axis)

Kuka · KR C4 extended

What does 26048 mean?

An overvoltage condition occurred during the charging phase of the KPP or KSP module for a specific axis. This could be due to excessive mains voltage or an insufficient number of connected capacitance modules.

Common Causes

  • Mains voltage is too high.
  • Too few capacitors connected (insufficient modules) for the system requirements.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure mains voltage and verify it is within specified limits.

  2. 2

    Verify the correct number of capacitor modules are connected.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.

Browse all codes in this manual (35)
Verified technical data. Last updated: April 2026

Related Faults

26030Device state: OK26031Internal error, KPP/KSP (axis)26032IxT overload error, KPP/KSP (axis)
Source: Kuka KR C4 extended
Open Manual (Page 234)Search more codes in this manual