EL
ErrorLib
Brands
||
  1. Home
  2. Kuka
  3. KR C4 extended
  4. 26122
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

26122

Fault in brake resistor, KPP/KSP (axis)

Kuka · KR C4 extended

What does 26122 mean?

The KPP module has detected an error in the ballast circuit, which typically includes the brake resistor. This indicates an issue with the energy dissipation components, potentially leading to overvoltage conditions if braking energy cannot be properly absorbed.

Common Causes

  • Ballast resistor fault.
  • Cabling between KPP and ballast resistor is damaged or improperly connected.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the ballast resistor for damage or overheating.

  2. 2

    Check cabling between the KPP and the ballast resistor for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.

Browse all codes in this manual (35)
Verified technical data. Last updated: April 2026

Related Faults

26030Device state: OK26031Internal error, KPP/KSP (axis)26032IxT overload error, KPP/KSP (axis)
Source: Kuka KR C4 extended
Open Manual (Page 238)Search more codes in this manual