10039

PROFIBUS Master Error in Module

Kuka · KR C4 PROFIBUS

What does 10039 mean?

The PROFIBUS master encountered an error within a specific module, identified by its name and further detailed by an internal error code. This suggests a component-specific issue on the PROFIBUS master. Refer to the PROFIBUS master's manufacturer documentation for details on the specific error code.

Common Causes

  • The PROFIBUS master detected an internal error within a specific slave module.
  • A slave module on the PROFIBUS network returned an invalid response to the master.
  • Corrupted data packets originating from or intended for the module.
  • The module's firmware is incompatible with the master's protocol version.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify the faulty module by its PROFIBUS address from the error message.

  2. 2

    Check the status indicator on the identified PROFIBUS module.

  3. 3

    Disconnect the problematic module from the PROFIBUS network and observe if the error clears.

  4. 4

    Review the PROFIBUS diagnostic logs for detailed information on the module's communication.

Browse all codes in this manual (19)