-2

Device Address Not Found

Kuka · KR C4 PROFIBUS

What does -2 mean?

The specified device address could not be located on the PROFIBUS. This can be due to an incorrect address parameter in the `ioCtl` call or the device not being present.

Common Causes

  • Device address configured in system does not match physical address on bus.
  • Device is not connected to the communication bus or is powered off.
  • Incorrect bus termination or signal integrity issues preventing device discovery.
  • Faulty device hardware preventing it from responding to address requests.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the `[device address]` parameter in the `ioCtl` command matches the Device ID configured in WorkVisual's Profibus settings (Page 18).

  2. 2

    Confirm the physical presence and correct wiring of the device on the PROFIBUS.