Invalid parameter changeover configuration
Lenze · i550 Protec Drive
What does 0x7695 mean?
This warning indicates that one or more parameters configured for the "Parameter change-over" function are no longer valid or usable. Consequently, the parameter change-over function is deactivated.
Common Causes
- Parameters referenced in the changeover function (e.g., P10.00, P11.00 for set 1 and set 2) no longer exist or have been renumbered after a firmware update.
- The target values or sources configured for parameter changeover are outside valid ranges or point to non-existent internal addresses.
- A parameter involved in the changeover mechanism has been set to an 'inactive' or 'disabled' state, rendering the function invalid.
- Dependency conflicts where one parameter changeover setting relies on another that is also being changed, leading to an ambiguous state.
- Memory corruption within the parameter storage or during saving, leading to invalid entries for the changeover function.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Access the parameter change-over configuration (e.g., P10.00, P11.00, P12.00) and review each referenced parameter for validity.
- 2
Re-configure the parameter change-over function from scratch, carefully selecting valid parameters and their corresponding values.
- 3
Compare the current parameter set to a previously saved, known-good configuration for the changeover function.
- 4
Perform a partial factory reset targeting only the parameter change-over block (if available), then reconfigure.
- 5
Update the inverter's firmware to the latest version to address potential software bugs related to parameter management.