E5

Remote Controller Signal Receive Error (Indoor Unit Side)

Mitsubishi Electric · PAR-21MAA MA Remote Controller

What does E5 mean?

The indoor unit has detected an error in receiving signals from the remote controller. This could be due to issues with the remote controller's wiring, the indoor unit's receiving circuit, or external electrical noise disrupting the communication line.

Common Causes

  • Indoor unit fails to receive signals from the remote controller.
  • Faulty wiring between the indoor unit and the remote controller.
  • Interference on the communication line.
  • Indoor unit's remote controller receiver is not functioning.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the connecting wire between the indoor unit and remote controller is connected correctly at both ends.

  2. 2

    Inspect the transmission wire of the remote controller for signs of electrical noise interference.

  3. 3

    Cycle power to the unit (turn off, then on again) to re-check for the error.

Browse all codes in this manual (26)
Verified technical data. Last updated: March 2026

Related Faults

Source: Mitsubishi Electric PAR-21MAA MA Remote Controller