E53

Suction Pipe Thermistor (Tho-S) Disconnected

Mitsubishi Electric · R410A Systems

What does E53 mean?

The suction pipe thermistor (Tho-S) on the outdoor unit is disconnected. This prevents the system from accurately monitoring suction line superheat, impacting operational safety, efficiency, and liquid floodback protection for the compressor.

Common Causes

  • Suction pipe thermistor (Tho-S) is disconnected or has a broken wire.
  • Faulty Tho-S sensor is providing an out-of-range reading.
  • Incorrect installation or loose connection of the Tho-S sensor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the connector for the Tho-S thermistor on the outdoor unit PCB — verify it is securely seated.

  2. 2

    Check the wiring connecting the Tho-S thermistor to the PCB for continuity and damage using a multimeter.

  3. 3

    Verify the thermistor is correctly attached to the suction pipe for proper thermal contact.