RHxx132

Device Read Command Error (CIP)

Omron · CS/CJ Series EtherNet/IP Driver

What does RHxx132 mean?

An error response was received by the system when attempting a device read command from the external device via CIP. This indicates a problem retrieving data using the CIP protocol, potentially affecting system monitoring or operation. The specific nature of the error may be detailed in the CIP Error Code field.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect EtherNet/IP network cabling between the Omron driver and the external device for damage, proper termination, and secure connections.

  2. 2

    Verify IP address, subnet mask, and gateway settings on both the Omron EtherNet/IP driver and the external device for correct configuration and network compatibility.

  3. 3

    Access the Omron EtherNet/IP driver's diagnostics or external device logs to retrieve the detailed CIP Error Code and identify the specific communication issue.

  4. 4

    Verify the CIP connection parameters within the Omron EtherNet/IP driver's configuration (e.g., connection path, instance IDs, data sizes) against the external device's specifications.

Browse all codes in this manual (11)