Omron · NJ/NY-series NC Integrated Controller
This informational event indicates that an error code was reported by a slave device following a Slave Error Detected (77860000 hex) event. The source is a CNC motor within the CNC Function Module. While the user program continues, the specific slave error may impact the CNC motor's operation, though the reporting event itself does not affect overall system operation. The actual slave error code is provided in the attached information.
Click steps to track your progress.
Examine the attached information, specifically attached information 1 (Slave error code), to identify the reported slave error code.
For OMRON 1S-series or G5-series Servo Drives, extract the lower two digits of the attached information to determine the main error display number (e.g., "13" from "FF13").
Refer to the specific manual for the identified slave device (e.g., Servo Drive manual) using the extracted slave error code to troubleshoot and correct the root cause.