Motor I2t

Motor I2t Protection Trip

Omron · SXF Inverter

What does Motor I2t mean?

This fault occurs when the VSD's internal thermal model (I²t calculation) determines that the motor's thermal capacity has been exceeded, indicating a prolonged overload condition. The drive trips to protect the motor from overheating and insulation damage. This is a critical protective function to prevent premature motor failure and costly repairs, especially during sustained operation above nominal current.

Common Causes

  • Prolonged motor overload condition, causing the VSD's internal thermal model (I²t) to determine excessive heating.
  • Incorrect motor rated current parameter (P1-04) set too low in the VSD, leading to premature thermal tripping.
  • Inadequate motor cooling (e.g., blocked cooling passages, fan failure) despite operating within rated current limits.
  • VSD I²t thermal model parameters (e.g., P1-51 motor thermal time constant) are not accurately tuned for the specific motor.
  • Repeated starts, stops, or frequent reversals exceeding the motor's specified duty cycle and thermal capacity.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure actual motor current (AOUT) on the VSD display and compare to the motor nameplate rated current (FLA). Reduce mechanical load if exceeding FLA.

  2. 2

    Verify VSD parameter P1-04 (motor rated current) exactly matches the motor nameplate FLA.

  3. 3

    Inspect motor cooling fan and fins for blockages. Ensure the ambient temperature around the motor is within specified limits.

  4. 4

    Adjust the motor thermal time constant parameter (P1-51) based on motor manufacturer data, or increase it by 10-20% as a temporary measure.

  5. 5

    Monitor the VSD's I²t thermal utilization (e.g., ITEMP on display) to understand thermal accumulation. Adjust operation to allow for cooling.

Browse all codes in this manual (32)
Verified technical data. Last updated: April 2026