Omron · SXF Inverter
An overvoltage condition has been detected in one of the power modules, indicating a voltage balancing error within the drive's internal architecture. This typically points to issues with the motor or inconsistencies in the line connections. Sustained overvoltage can damage the drive's internal components, especially the IGBTs and DC link capacitors, leading to drive failure.
Click steps to track your progress.
Monitor DC link voltage (e.g., parameter P0-01) during acceleration and deceleration cycles.
Verify the dynamic braking resistor is correctly sized and connected. Measure its resistance (e.g., 20 Ohms) and check connections at terminals +/BR.
Increase deceleration ramp time (e.g., P1-03) to reduce regenerative energy if applicable.
Check incoming mains supply for overvoltage conditions using a multimeter or power quality analyzer.
Inspect DC link capacitors for signs of damage or bulging.