EL
ErrorLib
Brands
||
  1. Home
  2. Omron
  3. SXF Inverter
  4. Power Fault
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

Power Fault

Undetermined Power Fault

Omron · SXF Inverter

What does Power Fault mean?

This trip indicates that one of the ten underlying Power Fault (PF) conditions has occurred, but the specific cause could not be precisely determined by the drive at the time of the trip. It acts as a general power-related error. Continuous occurrence without resolution suggests a deeper power stage issue that could escalate if ignored, leading to more critical failures.

Common Causes

  • Intermittent external hardware fault (e.g., loose power connection vibrating open).
  • Transient overcurrent or overvoltage event that clears before a specific fault code is registered.
  • Software or firmware anomaly preventing detailed fault detection.
  • Degradation of internal power monitoring circuitry.
  • Fluctuating mains supply outside of specified limits but not consistently triggering specific under/overvoltage faults.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all main power connections (input L1, L2, L3; output U, V, W; DC bus) for tightness and signs of overheating (discoloration).

  2. 2

    Review drive's fault log (e.g., parameter P1-09) for any recurring patterns or accompanying faults.

  3. 3

    Perform a full factory reset (e.g., P9-02 = 1) and reconfigure essential parameters from a known good backup.

  4. 4

    Monitor incoming mains voltage and current using a power quality analyzer to detect intermittent disturbances.

  5. 5

    Check for environmental factors like excessive vibration or temperature fluctuations impacting drive integrity.

Browse all codes in this manual (32)
Verified technical data. Last updated: April 2026

Related Faults

Brk FaultBrake Tripped on Fault or Not EngagedCom ErrorFieldbus/Serial Communication LostDC link errorDC Link Voltage Ripple Exceeds Maximum
Source: Omron SXF Inverter
View Official PDFSearch more codes in this manual