Uc

Underload

Schindler · Altivar 212 Variable Frequency Drive

What does Uc mean?

This fault indicates an underload condition where the measured motor current has dropped below the level set by parameter F611 ([Underload level]), potentially due to loss of load or mechanical failure.

Common Causes

  • The measured motor current has dropped below the level set by parameter F611.
  • Loss of mechanical load on the motor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check parameters F610 ([Underload det.]), F611 ([Underload level]), and F612 ([Underload det. time]) for correct settings.

  2. 2

    Verify the mechanical coupling between the motor and the load.