UP1

Undervoltage

Schindler · Altivar 212 Variable Frequency Drive

What does UP1 mean?

This fault indicates that the input voltage to the Altivar 212 drive is too low, potentially causing instability or improper operation. This can lead to a drive trip to prevent damage.

Common Causes

  • The input voltage to the drive is too low.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the input voltage at the drive terminals (R/L1, S/L2, T/L3) and rectify the supply trouble.

  2. 2

    Select the correct setting for parameter F627 ([Undervolt detect.]).

  3. 3

    Enable catch on the fly function (F301).

  4. 4

    Set parameter F302 ([Supply loss behav.]) to 2 (Freewheel).

Browse all codes in this manual (60)