Schneider Electric · Altivar 312 Variable Frequency Drive
The motor speed has exceeded its commanded or permissible limit, often due to an unstable control loop, an excessive regenerative load, or a mechanical runaway condition. This fault is critical as it can lead to mechanical damage to the driven equipment, create safety hazards, and result in a complete loss of control over the motor.
Click steps to track your progress.
1. Verify the encoder feedback cable connections at the drive terminals (e.g., A, A/, B, B/, Z, Z/) and the encoder are secure, clean, and properly shielded.
2. Monitor the actual motor speed feedback (e.g., via digital display or Modbus register) and compare it against the commanded speed (P1-01) for discrepancies.
3. Review and adjust PID control loop parameters (e.g., P1-10 Proportional Gain, P1-11 Integral Time) to ensure system stability; reduce gains incrementally.
4. Perform a mechanical inspection of the motor coupling to the driven load to ensure it is secure and not allowing the motor to overspeed independently.
5. Check the maximum speed limit (P1-06) parameter to ensure it is set appropriately for the application and the motor's rated speed.