Schneider Electric · Altivar Machine ATV340 Programming
This fault signifies a general internal malfunction within the drive controller, possibly related to internal circuitry or connections. Electromagnetic interference (EMI) can sometimes induce such faults, or it could be a hardware failure. Continued operation with an internal fault is not possible and requires immediate attention to prevent further damage or unexpected behavior.
Click steps to track your progress.
Cycle input power (L1, L2, L3) to the drive controller completely OFF for 5 minutes, then switch ON again.
Verify proper grounding of the drive controller and motor according to installation guidelines. Measure ground resistance.
Inspect the drive's internal components for visible damage (e.g., bulging capacitors, burnt resistors) if safe and accessible (power OFF).
Check all internal ribbon cable connections within the drive controller for secure seating and proper alignment (power OFF).
Review the input power quality for transient voltage spikes or sags using a power quality analyzer.