ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

12

Resolver 14-bit

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

What does 12 mean?

Emergency stop occurs because 14-bit resolver evaluation is active, and the actual motor speed exceeds 3600 1/min. The resolver feedback system is not designed for accurate operation above this speed.

Common Causes

  • The resolver feedback system is not providing valid or consistent positional data.
  • Faulty resolver or resolver interface board.
  • Signal interference or connection issues with the resolver wiring.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Set parameter P302 (Maximum speed 1) to a maximum value of 3600 1/min.

Browse all codes in this manual (78)
Verified technical data. Last updated: April 2026

Related Faults

00No error0000No error0010Illegal parameter index
Source: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)