31

TF Trip (Motor Overtemperature)

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

What does 31 mean?

No immediate drive response, but a fault is indicated, because the motor has become too hot and its TF (thermal feedback) sensor has tripped. This can also occur if the TF sensor is incorrectly connected or if the connection between the MOVIDRIVE and the motor's TF is interrupted.

Common Causes

  • Motor temperature has exceeded its safe operating limit (TF trip).
  • Overload condition causing excessive motor heat.
  • Faulty motor temperature sensor (PTC, KTY).
  • Insufficient cooling of the motor or drive.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Allow the motor to cool off to a safe operating temperature and then reset the error.

  2. 2

    Check all connections and the physical link between the MOVIDRIVE inverter and the motor's TF sensor.

  3. 3

    Set parameter P835 to 'No response' if the application requires ignoring the TF trip (use with caution as this bypasses protection).

Browse all codes in this manual (78)
Verified technical data. Last updated: April 2026