78

IPOS Software Limit Switch Exceeded

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

What does 78 mean?

No immediate drive response, but a fault is indicated, in IPOS operating mode if the programmed target position falls outside the travel range defined by software limit switches. This signifies a position command that attempts to move beyond the safety boundaries.

Common Causes

  • IPOS has commanded the motor beyond its configured software limits.
  • IPOS target position is outside the allowed travel range.
  • Software limit switch parameters (e.g., P2070, P2071) are set incorrectly.
  • Error in IPOS path planning exceeding limits.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the IPOS user program for target position commands that exceed defined limits.

  2. 2

    Verify the configured position of the software limit switches for correctness.