81

Start Condition Error (VFC Hoist)

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

What does 81 mean?

Immediate switch-off, specific to 'VFC hoist' operating mode, occurring when the motor cannot be supplied with the correct current during pre-magnetizing time. This typically happens if the rated motor power is too small relative to the inverter, or if the motor cable cross-section is insufficient.

Common Causes

  • Start condition for VFC Hoist application is not met.
  • Hoist motor cannot start due to safety or operational interlocks.
  • Incomplete setup of hoist application parameters.
  • External signal preventing hoist motor start.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check startup data and perform a new startup if necessary, ensuring the motor's rated power is compatible with the inverter's.

  2. 2

    Check the connection between the inverter and the motor for any resistance or poor contact.

  3. 3

    Check the cross-section of the motor cable and increase it if necessary to ensure adequate current delivery without excessive voltage drop.