ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

F109-42

Plausibility fault incorrect acceleration

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

What does F109-42 mean?

The current acceleration has exceeded the configured maximum acceleration limit. This indicates a discrepancy between actual motor dynamics and the set parameters, potentially due to incorrect configuration or mechanical issues.

Common Causes

  • Measured acceleration value exceeds plausible limits.
  • Encoder velocity or position data indicates unrealistic acceleration.
  • Incorrect configuration of acceleration monitoring parameters.
  • Sensor malfunction causing erratic acceleration readings.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the configuration (encoder screen: max. set speed).

  2. 2

    Analyze the speed/acceleration profile using the SCOPE function.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026