EL
ErrorLib
Brands
||
  1. Home
  2. SEW Eurodrive
  3. MOVIDRIVE MDX60B/61B Variable Speed Drive
  4. F109-56
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

F109-56

Plausibility fault in encoder interface (A3401 = encoder 1 and A3402 = encoder 2)

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

What does F109-56 mean?

The encoder interface (A3401 or A3402) does not match the configured data. This suggests a mismatch between the physical encoder type/connection and the drive's settings.

Common Causes

  • Encoder data plausibility check failed for encoder 1 (A3401) or encoder 2 (A3402).
  • Position or velocity feedback is inconsistent.
  • Encoder resolution mismatch or incorrect setup.
  • Mechanical issue causing inconsistent encoder output.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check encoder type and configuration (SSI/incremental).

  2. 2

    Check the encoder connection/wiring.

  3. 3

    Check the polarity of the encoder data.

  4. 4

    Check function of the encoder.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

F108-101Internal processing fault PROFIsafeF108-103Internal processing fault PROFIsafeF108-105Internal processing fault PROFIsafe
Source: SEW Eurodrive MOVIDRIVE MDX60B/61B Variable Speed Drive
Open Manual (Page 214)Search more codes in this manual