SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS
The motor has exceeded its safe operating temperature, triggering thermal monitoring. This can be due to environmental factors, excessive load, incorrect drive configuration, or the activation of an external winding thermostat. This error is triggered when the standard MOVIMOT® motor protection via DIP switch S1/5 set to 'ON' is deactivated, and an external TH connected to terminals X6:1,2,3 has tripped.
Click steps to track your progress.
Set DIP switch S1/5 to 'ON' if the MOVIMOT® inverter is installed close to the motor, to activate the appropriate protection mode
Check the connection of the external TH (winding thermostat) to terminals X6:1,2,3 and verify its status
Check the setting of DIP switch S1/6 for combinations of MOVIMOT® and motor with one lower power rating
Lower the ambient temperature around the motor
Prevent heat build-up around the motor by ensuring adequate ventilation
Reduce the load on the motor