97

Copy error (Parameter transmission error)

SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS

What does 97 mean?

An error occurred during the copying process of parameters (also referred to as parameter transmission error), potentially due to interruption of the connection or power supply during data transfer from a keypad or PC.

Common Causes

  • Disconnecting the DBG keypad or the PC during the parameter copying process
  • Switching the 24 V supply voltage off and on during the parameter copying process

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Load the factory setting from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error

  2. 2

    Load the complete data record from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error

Browse all codes in this manual (16)