90

Assignment of motor – inverter incorrect

SEW Eurodrive · [PDF] Operating Instructions

What does 90 mean?

The assigned motor type does not correctly match the MOVIMOT inverter, for example, an MM03 inverter paired with a DT71D4 motor. This mismatch can lead to incorrect operational characteristics, insufficient or improper motor protection, and potentially premature component failure or reduced performance.

Common Causes

  • Mismatched motor and inverter combination (e.g., MM03 – DT71D4).
  • Incorrect configuration or parameter assignment for the connected motor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the compatibility of the connected motor with the MOVIMOT frequency inverter model using the official product documentation or selection software.

  2. 2

    Check the inverter and motor nameplates to confirm the correct combination as per SEW-EURODRIVE specifications.

  3. 3

    Reset the fault by switching off the DC 24 V supply voltage to the inverter for at least 10 seconds.

Browse all codes in this manual (11)