F109-42

Plausibility fault incorrect acceleration

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

What does F109-42 mean?

The current acceleration has exceeded the configured maximum acceleration limit. This indicates a discrepancy between actual motor dynamics and the set parameters, potentially due to incorrect configuration or mechanical issues.

Common Causes

  • Measured acceleration value exceeds plausible limits.
  • Encoder velocity or position data indicates unrealistic acceleration.
  • Incorrect configuration of acceleration monitoring parameters.
  • Sensor malfunction causing erratic acceleration readings.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the configuration (encoder screen: max. set speed).

  2. 2

    Analyze the speed/acceleration profile using the SCOPE function.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults