F109-56
Plausibility fault in encoder interface (A3401 = encoder 1 and A3402 = encoder 2)
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
What does F109-56 mean?
The encoder interface (A3401 or A3402) does not match the configured data. This suggests a mismatch between the physical encoder type/connection and the drive's settings.
Common Causes
- Encoder data plausibility check failed for encoder 1 (A3401) or encoder 2 (A3402).
- Position or velocity feedback is inconsistent.
- Encoder resolution mismatch or incorrect setup.
- Mechanical issue causing inconsistent encoder output.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check encoder type and configuration (SSI/incremental).
- 2
Check the encoder connection/wiring.
- 3
Check the polarity of the encoder data.
- 4
Check function of the encoder.
Verified technical data. Last updated: March 2026
Related Faults
Source: SEW Eurodrive MOVIDRIVE MDX60B/61B Variable Speed Drive