This alarm signals that the data for the currently active workpiece probe is either incorrect or the probe itself is inactive. Error code 'A' indicates an inactive workpiece probe or tool edge, while 'B' signifies that the probe's length L1 is zero. This issue prevents accurate workpiece measurement and can lead to machining errors if not corrected, impacting precision and quality.
Click steps to track your progress.
1. Verify that the workpiece probe is correctly selected and activated in the NC program using the appropriate M-code or dedicated function.
2. Inspect the active tool data (T-data) for the workpiece probe, ensuring all values like length (L1, L2) and radius are accurate.
3. Check the communication link and power status (e.g., battery level for wireless probes, cable continuity for wired probes) of the workpiece probe.
4. Perform a manual probe trigger test to confirm the probe is mechanically sound and generates a signal upon contact.
5. Review and correct the machine data (MDs) or NC parameters that define the workpiece probe characteristics and measurement cycles.
6. If physical damage is suspected, replace the probe stylus or, if available, substitute with a known good workpiece probe for testing.