Siemens · SINAMICS G120C Variable Speed Drive
The drive-integrated "Safety Integrated" function on processor 1 has detected an error and initiated a STOP A. This typically occurs due to an unsuccessful safety shutdown path check or as a consequence of F01611. This fault indicates a critical issue with the safety system, preventing drive operation and requiring immediate attention to ensure machine and personnel safety.
Click steps to track your progress.
Verify the status of all connected external safety components (e.g., E-stop, safety light curtains, safety door switches) for activation.
Check the wiring integrity of the safety circuit, specifically the connections to the STO inputs (e.g., X1, X2 terminals on safety module).
Review the drive's safety log (r9700) for specific details on the triggering event and the status of internal safety signals.
Initiate a forced checking procedure (FCP) via parameter P9500 to confirm the functionality of the safety output path.