Siemens · SINAMICS G120C Variable Speed Drive
The internal cooling fan of the power unit has failed and is likely defective. Proper cooling is crucial for maintaining the power unit's operational temperature. A malfunctioning fan leads to inadequate heat dissipation, risking severe overheating, thermal trips, reduced performance, and potentially permanent damage to the power unit if not replaced.
Click steps to track your progress.
Visually inspect the power unit's internal cooling fan(s) for physical damage to blades or accumulation of dust/debris.
Check the fan's electrical connection to the power unit's control board for looseness or corrosion.
Attempt to manually rotate the fan blades (with power off) to check for free movement and absence of obstructions.
Measure the fan's supply voltage (e.g., 24VDC or 48VDC) at its connector when the drive is commanded to run.
Replace the internal cooling fan unit with an OEM approved spare part.