EL
ErrorLib
Brands
||
  1. Home
  2. SMA
  3. SUNNY BOY 5000US-8000US Solar Inverter
  4. EarthCurMax-S
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

EarthCurMax-S

SRR-Related Earth Current Exceeds Tolerable Range

SMA · SUNNY BOY 5000US-8000US Solar Inverter

What does EarthCurMax-S mean?

The earth current between the PV+ conductor and ground (GND), monitored by the SRR (Stromregelungsrechner), has exceeded its acceptable operating range in the Sunny Boy SB50US-80US-IUS094030. This indicates a ground fault in the PV array. The inverter will disconnect from the grid.

Common Causes

  • Ground fault in the PV array detected by the SRR.
  • Ground fault current exceeding 1 Amp.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Switch off the external DC disconnect to the Sunny Boy SB50US-80US-IUS094030.

  2. 2

    Switch off the main AC circuit breaker connecting the Sunny Boy to the grid.

  3. 3

    Troubleshoot the PV array to locate and clear the ground fault.

  4. 4

    Manually clear the ground fault error on the user interface display after correction.

Browse all codes in this manual (23)
Verified technical data. Last updated: April 2026

Related Faults

Bfr-SrrMicro-controller Communication FailureDeratingInverter Output Power Reduction Due to High TemperatureEEPROMEEPROM Non-Essential Data Access Failure
Source: SMA SUNNY BOY 5000US-8000US Solar Inverter
Open Manual (Page 87)Search more codes in this manual