7619

Communication fault with meter unit

SMA · Sunny Boy Solar Inverter

What does 7619 mean?

The inverter is not receiving any data from the connected energy meter. This fault indicates a disruption in the communication link between the inverter and the meter, preventing accurate energy monitoring.

Common Causes

  • Incorrect integration of the energy meter into the network with the inverter.
  • Poor WLAN connection quality if using a wireless connection.
  • Inverter not connected to the DHCP server (router) via Ethernet if using a wired connection.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure the energy meter is correctly integrated into the same network as the inverter (refer to energy meter manual).

  2. 2

    For WLAN connection: Improve WLAN connection quality (e.g. via WLAN repeater).

  3. 3

    For WLAN connection: Connect the inverter with the DHCP server (router) via Ethernet.