What does 15 mean?
The motor stall protection has tripped, indicating that the motor is unable to rotate freely or maintain its commanded speed due to excessive load. This suggests a mechanical obstruction or an overload condition that prevents the motor from achieving motion.
Common Causes
- Motor shaft rotation is blocked or severely restricted.
- Overly high starting torque demand.
- Mechanical binding in the driven equipment.
- Incorrect motor tuning parameters (P1-10 to P1-15).
- Low supply voltage affecting motor torque.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the motor shaft and connected mechanical load to ensure the motor is able to rotate freely without any obstructions.
- 2
Verify that the mechanical load on the motor does not exceed its rated capacity.