63
Emergency Stop Command
Vacon · NX All-in-One Application
What does 63 mean?
An emergency stop command has been received either through a digital input or via the fieldbus network. This safety mechanism instantly halts the drive and requires a system reset before further operation is permitted.
Common Causes
- Emergency stop button pressed or circuit activated.
- External emergency stop signal received.
- Internal emergency stop logic triggered by safety conditions.
- Software emergency stop command issued.
- Wiring fault in the emergency stop circuit.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Identify and resolve the condition that triggered the emergency stop command from the digital input or fieldbus.
- 2
Perform a drive reset to clear the fault and enable acceptance of a new run command.
Verified technical data. Last updated: March 2026