13

Frequency converter undertemperature

Vacon · NXP/C

What does 13 mean?

The heatsink temperature of the frequency converter has fallen below –10 °C. Operating the drive outside its specified temperature range can impact component performance and lifespan.

Common Causes

  • Internal temperature of the frequency converter too low.
  • Ambient temperature below operating range.
  • Faulty temperature sensor (P1-30) in the converter.
  • Inadequate ventilation or blocked airflow.
  • Low load operation leading to reduced internal heating.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the ambient temperature around the frequency converter's heatsink and ensure it is maintained above –10 °C.

  2. 2

    Check the functionality of any cabinet heaters or temperature regulation systems in the drive's enclosure, if applicable.

Browse all codes in this manual (11)