CPF02

A/D Conversion Error

Yaskawa · Drive Fault Codes

What does CPF02 mean?

An error in the Analog-to-Digital (A/D) conversion circuit, which is responsible for converting analog input signals (e.g., speed reference, feedback) into digital values for the drive's control system. This impacts the accuracy or availability of analog inputs, potentially leading to incorrect operation.

Common Causes

  • Faulty A/D converter chip on the control board due to component failure
  • Excessive noise or interference on analog input lines leading to corrupted readings
  • Damaged analog input circuitry on the drive's control board.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check for external noise sources near analog input wiring and ensure proper shielding and grounding.

  2. 2

    Verify stability of the analog input signal source (e.g., 0-10VDC or 4-20mA) with a multimeter.

  3. 3

    Cycle power to the drive to reset the control circuit and reinitialize the A/D converter.

Browse all codes in this manual (60)