Yaskawa · J1000
A self-diagnostic error has occurred within the drive's control circuit. This indicates an internal problem with the drive's core control logic, which is critical for all operations. This fault can lead to unpredictable drive behavior, unstable control, or complete operational shutdown if not addressed.
Click steps to track your progress.
Perform a full power cycle of the drive (turn off main input power for 30 seconds, then reapply).
Check input voltage stability at terminals R/L1, S/L2, T/L3 using a multimeter during operation.
Inspect all internal ribbon cables and connectors on the control board for secure seating and visible damage.
Review the drive's event log or fault history for preceding faults.
Attempt to reinitialize all parameters to factory defaults (e.g., using A1-03 = 2220) and re-enter settings.
If the fault persists, professional drive repair or replacement of the control board or entire drive may be necessary.