F3

Power Loss

Allen-Bradley · PowerFlex 4 Adjustable Frequency

¿Qué significa F3 ?

This fault occurs when the drive detects a low voltage condition or an interruption on the incoming AC power line. This can lead to unstable operation or unexpected shutdowns.

Causas comunes

  • Complete loss of primary power to the drive.
  • Internal power supply failure within the unit.
  • Main fuse blown or circuit breaker tripped.
  • AC mains supply failure.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure the incoming AC line voltage at the drive input terminals (L1, L2, L3) to identify any sag or interruption.

  2. 2

    Verify the integrity of the upstream power supply and circuit breakers feeding the drive.