25

OverSpeed Limit

Allen-Bradley · PowerFlex 700

¿Qué significa 25 ?

Functions like Slip Compensation or Bus Regulation have attempted to add an output frequency adjustment greater than that programmed in [Overspeed Limit]. This occurs when the drive tries to exceed its configured maximum speed due to an external force (overhauling load) or control algorithm, potentially leading to instability.

Causas comunes

  • Motor speed exceeds the configured overspeed limit (e.g., P3-02).
  • Runaway motor condition due to loss of control.
  • Incorrect encoder feedback indicating higher speed than actual.
  • External control signal commanding excessive speed.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Remove excessive load or overhauling conditions on the motor.

  2. 2

    Increase the value of the [Overspeed Limit] parameter.

Ver todos los códigos en este manual (49)