¿Qué significa 69 ?
The measured resistance of the internal Dynamic Braking (DB) resistor is outside its specified operating range. This could indicate a damaged or incorrect braking resistor, preventing effective energy dissipation during deceleration. A faulty DB resistor can lead to overvoltage trips or poor braking performance.
Causas comunes
- Braking resistor fault or excessive temperature detected.
- Braking resistor value out of specified range.
- Braking resistor connected improperly or shorted.
- Excessive regenerative energy requiring braking resistor activation.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Replace the internal Dynamic Braking resistor with a specified replacement part.
Datos técnicos verificados. Última actualización: March 2026