Traduciendo...
70

Power Unit Fault

Allen-Bradley · PowerFlex 700

¿Qué significa 70 ?

One or more of the output transistors were operating in the active region instead of desaturation. This can be caused by excessive transistor current or insufficient base drive voltage, indicating a failure within the drive's output power stage.

Causas comunes

  • Malfunction within the power conversion or regulation stage.
  • Overload condition exceeding the power unit's capacity.
  • Internal component failure in the power stage.
  • Inadequate cooling of the power unit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check for damaged output transistors (e.g., using a multimeter for short circuits).

  2. 2

    Replace the drive unit.

Ver todos los códigos en este manual (49)
Datos técnicos verificados. Última actualización: March 2026