91

Encoder Loss

Allen-Bradley · PowerFlex 700

¿Qué significa 91 ?

Requires a differential encoder. One of the two encoder channel signals (e.g., A or B) is missing. This indicates a problem with the encoder feedback, which is critical for precise motor control, leading to loss of speed or position regulation.

Causas comunes

  • Encoder cable disconnected or damaged.
  • Encoder power supply failure (e.g., 24VDC).
  • Faulty encoder module.
  • Interference on encoder feedback lines.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify encoder wiring for continuity and proper connections at the drive's encoder input terminals.

  2. 2

    Replace the encoder unit.

Ver todos los códigos en este manual (49)