Diag3:lit, Diag4:off

Internal Terminal Error (μC2)

Beckhoff · EL6900 Operating Instructions

¿Qué significa Diag3:lit, Diag4:off ?

This LED combination (Diag 3 lit, Diag 4 off) indicates an internal error related to microcontroller 2 (μC2) of the terminal. This is a global fault, leading to the shutdown of the terminal. Similar to μC1 errors, these faults typically require inspection by the manufacturer.

Causas comunes

  • An internal error or fault has occurred within the second microcontroller (μC2) of the terminal, or μC1 is operational.
  • Hardware failure or software issue specifically affecting the secondary processing unit.
  • μC1 is functioning, but μC2 has detected an internal anomaly.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Record the exact LED states (Diag 3 lit, Diag 4 off) for documentation.

  2. 2

    Power cycle the EL6900 terminal and observe if the fault clears or reoccurs immediately upon restart.

  3. 3

    Access the TwinCAT System Manager to check for any additional diagnostic messages or system events logged by the EL6900 prior to the shutdown.