Severe Fault (Safety Project State)
Beckhoff · EL6900 Operating Instructions
¿Qué significa F100:01 (7) ?
This code, corresponding to State '7' of CoE object F100:01 (Safety Project State), signifies that the EL6900 has switched off due to a severe internal fault. In this state, a safety project cannot be loaded or started. This indicates a critical error in the safety logic execution or hardware that has led to a fail-safe shutdown.
Causas comunes
- The safety system is in an invalid or uninitialized state, preventing operation.
- The safety project loaded into the device is not active or has a critical configuration error.
- Safety interlocks have not been correctly acknowledged or are in an unsafe state.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review the TwinCAT System Manager logs for any additional diagnostic messages specifically related to the EL6900.
- 2
Check for any recent changes in the EtherCAT configuration or safety project that might trigger a severe internal fault.
- 3
Verify the integrity of the safety project currently loaded or attempted to be loaded on the EL6900.