Traduciendo...
F2179

Modulo limitation error of measuring encoder

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F2179 ?

A modulo limitation error has occurred with the measuring encoder. This means the measuring encoder's reported position has gone outside its defined modulo operating range, or experienced an unexpected position wrap. This can lead to highly inaccurate position measurements, impacting critical machine operations and product quality.

Causas comunes

  • Incorrect modulo parameters configured for the measuring encoder
  • Measuring encoder counting issues or skipped pulses
  • Physical movement exceeding measuring encoder modulo range limits
  • Software error in measuring encoder modulo position calculation
  • Noise causing erroneous measuring encoder readings

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the encoder supply voltage at the drive's encoder feedback connector against specified values.

  2. 2

    Inspect the encoder feedback cable for damage, proper shielding, and secure connections at the encoder and drive.

  3. 3

    Check the drive parameters for the measuring encoder configuration, including encoder type, resolution, and modulo range settings, against machine documentation.

  4. 4

    Inspect the mechanical mounting and coupling of the measuring encoder for looseness or misalignment that could cause position discrepancies.

Ver todos los códigos en este manual (99)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive MPx02