Refer. missing when selecting safety related end pos.
Bosch Rexroth · IndraDrive MPx02
¿Qué significa F3111 ?
This non-fatal safety technology error indicates that a safety-related reference or datum is missing when attempting to select a safety-related end position. This prevents the drive from reliably establishing its safe operating limits, impacting safety functions like Safe Limited Position (SLP).
Causas comunes
- Safety reference point for the axis has not been set or is corrupted.
- Encoder fault preventing accurate position feedback for safety functions.
- Incorrect configuration of safety parameters related to reference positions (e.g., S-0-0193, S-0-0194).
- Problem with the safety encoder or its connection to the IndraDrive MPx02.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the safety reference point for the axis has been correctly established and stored according to the machine's commissioning procedure.
- 2
Check the primary and secondary encoder feedback signals for integrity and proper operation.
- 3
Review safety parameters in the IndraDrive MPx02, specifically those defining reference positions and safety limits, to ensure correct configuration.
- 4
Inspect the wiring and connections of the safety encoder for damage, loose terminals, or improper shielding.
- 5
If an external safety PLC is used, verify its programming and communication with the IndraDrive MPx02 regarding reference position management.