F3142

Activation time of enabling control exceeded

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F3142 ?

This non-fatal safety error indicates that the time taken to activate the enabling control (e.g., Safe Torque Off - STO) on the IndraDrive MPx02 has exceeded its permissible limit. This suggests a delay in the safety circuit's response, which can compromise the safety function's effectiveness.

Causas comunes

  • Slow response of external safety relays or contactors in the enabling circuit.
  • Excessive capacitance or inductance in the enabling circuit wiring.
  • Incorrect parameterization of the activation time monitoring in the IndraDrive MPx02.
  • Partial short circuit or high resistance in the enabling circuit.
  • Internal hardware fault in the safety-related input or STO circuit of the drive.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure the actual response time of the external safety relays or contactors involved in the enabling circuit.

  2. 2

    Inspect the wiring of the enabling control circuit for excessive length, insufficient wire gauge, or poor connections that could cause delays.

  3. 3

    Verify the configured activation time monitoring parameters in the IndraDrive MPx02 to ensure they are appropriate for the system's response.

  4. 4

    Check the enabling circuit for any partial shorts or high resistance connections that could impede signal activation.

  5. 5

    If the error persists and external components are verified, it may indicate an internal issue with the STO input section of the IndraDrive MPx02.

Ver todos los códigos en este manual (99)