Safety command for system halt incorrect
Bosch Rexroth · IndraDrive MPx02
¿Qué significa F3151 ?
This non-fatal safety error indicates that the command received by the IndraDrive MPx02 to initiate a safety-related system halt is incorrect or invalid. This implies a failure in the safe shutdown process, which is critical for machine safety.
Causas comunes
- Incorrect sequence or timing of the safety halt command from the master controller or safety PLC.
- Mismatch between the expected and received safety halt command (e.g., wrong bit pattern or value).
- Communication error preventing the correct safety halt command from reaching the IndraDrive MPx02.
- Incorrect parameterization of the safety halt logic.
- Failure of internal safety logic to correctly process the halt command.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the exact sequence, timing, and value of the safety system halt command being sent by the master controller or safety PLC.
- 2
Check safety parameters in the IndraDrive MPx02 related to safety halt logic and response.
- 3
Inspect the communication link between the master controller and the IndraDrive MPx02 for errors.
- 4
Ensure that any external safety devices triggering the halt command are functioning correctly.
- 5
If the error persists despite correct external commands, a power cycle of the IndraDrive MPx02 may be necessary to clear internal logic states.